Steady Flow to Wells

A pumped well pulls the water table into a cone, and the cone's shape gives the flow.

Before this Lesson

A town drills a new well through 30 ft of clay into a 45 ft layer of sand and pumps it at a steady 500 gpm. For a day or so, the water in two monitoring wells nearby keeps sinking. Then it stops. The one 40 ft from the pumping well has settled 8.1 ft below where it started, and the one 160 ft away, 3.6 ft.

A lab permeameter tests a few inches of soil. This test just sampled the aquifer itself, and those numbers say how readily it passes water. Reading them takes nothing more than Darcy's law, applied to water arriving from every direction at once.

The cone of depression

Before the pump starts, a well's water stands at the aquifer's undisturbed level: the water table, or in a confined aquifer, the piezometric surface, as in Groundwater and Darcy's Law. Start pumping and the level in the well drops, so water flows toward it from every side, and the levels nearby sink too: a lot close to the well, less farther out. That dimple is the cone of depression, and how far the level has dropped at any point is the drawdown ss.

At first the cone deepens and spreads. Soon it spreads so slowly that the levels stop changing, and the well is at steady state: the aquifer delivers what the pump removes. The equations here all describe that settled cone.

Why a cone? Picture the aquifer as nested cylinders centered on the well. Water headed for the well passes through every one, so at steady state the same flow QQ crosses each.

r 2r 4r Well
Every ring around the well passes the same flow
The same twelve flow lines cross each ring. The ring at r is a quarter the size of the ring at 4r, so the lines crowd four times closer there.

In a confined aquifer of thickness bb, a cylinder of radius rr has a side area of 2πrb2\pi r b. The cylinder 10 ft out has a tenth the area of the one 100 ft out, so the same flow needs ten times the Darcy velocity there, and in Darcy's law, Q=KiAQ = KiA, more velocity takes more gradient:

i=Q2πrbKi = \frac{Q}{2\pi r b K}

The gradient goes as 1/r1/r: gentle far from the well, steep close to it. That's the cone.

Now follow the head outward. From rr to 2r2r, the water covers a distance rr. From 2r2r to 4r4r, it covers twice that distance at half the gradient, so the head rises by the same amount. Every doubling of the distance adds the same rise in head, whether it's from 10 ft to 20 ft or from 1,000 ft to 2,000 ft.

20 40 80 160 320 0 2 4 6 8 10 12 Distance from the well, r (ft) Drawdown, s (ft) R
Each doubling of distance, 2 ft less drawdown
From 20 ft to 40 ft and from 160 ft to 320 ft, the drawdown falls the same 2 ft, though the second stretch is eight times as long. R marks where the cone ends.

A quantity that rises by the same step each time its input doubles is a logarithm, which counts multiplications, as in Exponentials and Logarithms. That's the natural log in every well equation. In calculus terms, Darcy's law for the cylinder at rr is Q=K (dh/dr)(2πrb)Q = K\,(dh/dr)(2\pi r b), and integrating between two radii gives

h2−h1=Q2πKb∫r1r2drr=Q2πKb ln⁡r2r1h_2 - h_1 = \frac{Q}{2\pi K b}\int_{r_1}^{r_2}\frac{dr}{r} = \frac{Q}{2\pi K b}\,\ln\frac{r_2}{r_1}

Confined aquifers: the Thiem equation

Solve that for QQ and you have the Thiem equation, from the Handbook's Well Drawdown section:

Q=2πT (h2−h1)ln⁡(r2/r1)T=KbQ = \frac{2\pi T\,(h_2 - h_1)}{\ln(r_2/r_1)} \qquad T = Kb

The product KbKb is the transmissivity TT, in ft²/day or m²/day. KK says how readily the soil passes water, and TT says how readily the aquifer's whole thickness does. A thin gravel and a thick sand can share the same TT, and then they feed a well the same way.

Q r1 r2 h1 s1 h2 s2 b H Ground surface Original piezometric surface Aquitard Confined aquifer Pumped piezometric surface Impermeable
Heads and drawdowns in a confined aquifer

Adapted from the FE Reference Handbook, Well Drawdown

The Handbook measures h1h_1 and h2h_2, the heights of the piezometric surface, from the bottom of the aquifer, at radii r1r_1 and r2r_2 from the pumping well. Make 1 the nearer point and 2 the farther. The head rises away from the well, so h2>h1h_2 > h_1, and the difference and the log both come out positive. Swap one pair and not the other, and QQ comes out negative, which at least warns you.

Only the difference h2−h1h_2 - h_1 appears, so in a confined aquifer the datum doesn't matter. A drawdown is the original head HH less the present one, s=H−hs = H - h, so

h2−h1=(H−s2)−(H−s1)=s1−s2h_2 - h_1 = (H - s_2) - (H - s_1) = s_1 - s_2

and you can work with drawdowns directly. The log must be natural: with log⁡10\log_{10} in its place, QQ comes out 2.3 times too large.

The Handbook lists QQ in cfs and KK in ft/sec, but any consistent units work. With KK in ft/day and lengths in feet, QQ comes out in ft³/day. A rate in gpm converts with the Handbook's 7.481 gal per ft³, so 1 gpm is 1,440/7.481=192.51{,}440/7.481 = 192.5 ft³/day.

Worked Example Reading the pumping test
1 of 2

The town's well from the opening pumps 500 gpm from a confined sand aquifer 45 ft thick. At steady state, the drawdown is 8.1 ft at an observation well 40 ft away and 3.6 ft at one 160 ft away. Find the aquifer's transmissivity and hydraulic conductivity.

Unconfined aquifers: the Dupuit equation

In an unconfined aquifer, the cone forms in the water table itself, and the water table is the top of the saturated soil. So the water doesn't flow through a fixed thickness bb. At radius rr it flows through hh, the height of the water table above the bottom of the aquifer. Near the well, where the water table is drawn down, the cylinders are short as well as narrow.

Q r1 r2 h1 h2 H Ground surface Original water table Unconfined aquifer Pumped water table Impermeable
Heads in an unconfined aquifer

Adapted from the FE Reference Handbook, Well Drawdown

That puts hh into Darcy's law twice: once as the head that drives the flow, and once as the height of the area it flows through.

Q=K dhdr (2πrh)Q = K\,\frac{dh}{dr}\,(2\pi r h)

Move that hh over to the dhdh and integrate. h dhh\,dh integrates to h2/2h^2/2, which is where the squares come from:

h22−h122=Q2πK ln⁡r2r1\frac{h_2^2 - h_1^2}{2} = \frac{Q}{2\pi K}\,\ln\frac{r_2}{r_1}

Solved for the flow, that's Dupuit's formula as the Handbook prints it:

Q=πK (h22−h12)ln⁡(r2/r1)Q = \frac{\pi K\,(h_2^2 - h_1^2)}{\ln(r_2/r_1)}

The Handbook defines h1h_1 at the well itself, with r1r_1 the well's radius, but the derivation holds between any two radii, and a pumping test uses two observation wells.

The squares look like a different kind of equation until you factor them, h22−h12=(h2+h1)(h2−h1)h_2^2 - h_1^2 = (h_2 + h_1)(h_2 - h_1):

Q=2πK(h1+h22)(h2−h1)ln⁡(r2/r1)Q = \frac{2\pi K \left(\frac{h_1 + h_2}{2}\right)(h_2 - h_1)}{\ln(r_2/r_1)}

That's the Thiem equation, with the average saturated thickness between the two wells standing in for bb. It also shows why the heads have to be measured from the bottom of the aquifer. In the confined equation, hh only drives the flow, so any datum works. Here it's also a thickness, and a thickness starts at the bottom. A water level given as a depth below the ground, or as a drawdown, has to become a height above the aquifer's base before you square it.

Worked Example Pumping rate from an unconfined aquifer
1 of 2

A well fully penetrates an unconfined sand aquifer that rests on clay, with a hydraulic conductivity of 60 ft/day. At steady pumping, observation wells 30 ft and 150 ft away show the water table 52.0 ft and 56.0 ft above the clay. Find the pumping rate in gpm.

Head and drawdown at any radius

At some distance RR, called the radius of influence, the cone fades into the undisturbed level, and the head there is still its original value HH. The Handbook doesn't name RR, but problems state it. Use RR and HH as the far point in either equation. In a confined aquifer, the drawdown at any radius rr is

s=H−h=Q2πT ln⁡Rrs = H - h = \frac{Q}{2\pi T}\,\ln\frac{R}{r}

and in an unconfined one, where HH is the saturated thickness before pumping,

H2−h2=QπK ln⁡RrH^2 - h^2 = \frac{Q}{\pi K}\,\ln\frac{R}{r}

At the well itself, rr is the well's radius rwr_w, half its diameter. The log is largest there, so the drawdown is the deepest in the cone.

RR is partly a convenience. In an aquifer with no edges, the cone never quite stops spreading. It just spreads ever more slowly, so the shape of the cone near the well settles. Since RR sits inside a log, its exact value matters little: doubling it adds only ln⁡2=0.69\ln 2 = 0.69 to a log that's often 5 to 8 at the well.

Two judgments follow from these equations. In a confined aquifer, the drawdown is proportional to QQ: pump twice as hard and every point in the cone drops twice as far. In an unconfined aquifer it drops a little more than that, because the drained aquifer gets thinner and the water has less area to pass through. With distance, the drawdown falls by equal steps for each doubling, not for each foot.

Worked Example Drawdown in the well and 100 ft out
1 of 2

A 12 in. diameter well pumps 300 gpm from a confined aquifer with a transmissivity of 3,000 ft²/day, and the radius of influence is 1,500 ft. Find the drawdown in the well and 100 ft from it.

Specific capacity

Well owners track a simpler number: how much water the well gives per foot of drawdown in the well itself. The Handbook's Well Drawdown section calls it the specific capacity, Q/DwQ/D_w, where DwD_w is the well drawdown, the sws_w above. A well yielding 400 gpm with 16 ft of drawdown has a specific capacity of 25 gpm/ft.

In a confined aquifer, the well's drawdown is proportional to the rate, so ideally the specific capacity stays the same at any rate, and it predicts the drawdown at a new one. A specific capacity that falls over the years is a classic sign of a clogging well screen.

Checkpoint
1 of 2

A confined gravelly sand aquifer is 12 m thick, with a hydraulic conductivity of 0.040 cm/s. What is its transmissivity?

m²/day

Confined or unconfined?

Both equations come from the same cylinders and carry the same natural log. What separates them is whether the thickness the water flows through stays put. Under an aquitard it does, so the heads enter plainly. Under a water table it shrinks with the cone, so the heads are squared. A sketch tells you which: in a confined aquifer, the water in the wells stands above the aquifer's top.

Choosing the well equation
ConfinedUnconfined
Upper boundaryAquitardWater table
Water in a wellAbove the aquifer's topAt the water table
Flow area at r2πrb2\pi r b2πrh2\pi r h
EquationQ=2πT(h2−h1)/ln⁡(r2/r1)Q = 2\pi T(h_2 - h_1)/\ln(r_2/r_1)Q=πK(h22−h12)/ln⁡(r2/r1)Q = \pi K(h_2^2 - h_1^2)/\ln(r_2/r_1)
Heads measured fromAny datumAquifer bottom
Checkpoint
1 of 2
Q 30 ft 120 ft 8.6 ft 5.9 ft 20 ft 35 ft Ground surface Clay Sand Shale
A pumping test site

A well at the site sketched above pumps at a steady rate, and the sand's hydraulic conductivity is 90 ft/day. The depths shown are to the water levels at steady state. Which expression gives the pumping rate in ft³/day?

A.
Q=π(90)(49.12−46.42)/ln⁡(120/30)Q = \pi(90)(49.1^2 - 46.4^2)/\ln(120/30)
B.
Q=2π(90)(35)(8.6−5.9)/log⁡10(120/30)Q = 2\pi(90)(35)(8.6 - 5.9)/\log_{10}(120/30)
C.
Q=2π(90)(35)(49.1−46.4)/ln⁡(120/30)Q = 2\pi(90)(35)(49.1 - 46.4)/\ln(120/30)
D.
Q=π(90)(8.62−5.92)/ln⁡(120/30)Q = \pi(90)(8.6^2 - 5.9^2)/\ln(120/30)

Recap

  • The same QQ crosses every cylinder around a well, so the gradient steepens toward it as 1/r1/r, and each doubling of distance adds the same rise in head. That's the natural log.
  • Confined: Q=2πT(h2−h1)/ln⁡(r2/r1)Q = 2\pi T(h_2 - h_1)/\ln(r_2/r_1), with T=KbT = Kb. Any datum works, and h2−h1=s1−s2h_2 - h_1 = s_1 - s_2.
  • Unconfined: Q=πK(h22−h12)/ln⁡(r2/r1)Q = \pi K(h_2^2 - h_1^2)/\ln(r_2/r_1), with heads measured from the aquifer bottom and squared, because hh is also the thickness the water flows through.
  • With RR and HH as the far point, s=(Q/2πT)ln⁡(R/r)s = (Q/2\pi T)\ln(R/r) or H2−h2=(Q/πK)ln⁡(R/r)H^2 - h^2 = (Q/\pi K)\ln(R/r). Confined drawdown is proportional to QQ and falls by equal steps per doubling of distance.
  • Specific capacity is Q/DwQ/D_w, the yield per foot of drawdown in the well.