Pipe Friction
Friction depends on whether the flow is orderly or chaotic, and the Reynolds number tells you which.
Before this Lesson
In 1883, Osborne Reynolds ran water from a tank through a long glass tube and fed a thin thread of dye into its mouth. With the valve barely open, the thread ran down the tube as straight as a wire. He opened the valve further, and the thread began to waver, then burst into a cloud that filled the pipe.
Same tube, same water, only faster. The water went from sliding in orderly layers to tumbling in eddies, and the two rub against the pipe differently. That difference sets the friction loss , which the energy equation has so far been handed.
Orderly or chaotic
Why should speed matter? Picture a small parcel of water knocked a little sideways by a bump in the wall. Its momentum carries it on into its neighbors, and they shove theirs, so a wobble tends to grow into an eddy. Viscosity fights back. Each layer drags on the layers beside it, and that drag smooths a wobble out before it can grow. The flow stays orderly as long as viscosity wins.
So compare the two. Inertia, the stubbornness of moving mass, scales as . Viscous stress is times a velocity gradient, and across a pipe that gradient is about , so it scales as . Their ratio is the Reynolds number:
That's how the Handbook prints it under Reynolds Number, with the kinematic viscosity . Its Similitude section writes the same ratio as the inertia force over the viscous force, . A large Re means inertia wins and wobbles grow, and a small one means viscosity damps them. Re has no units, so it means the same thing in any fluid and any pipe. For flow in a pipe, the Handbook draws the lines here:
- laminar for
- transitional for
- fully turbulent for
Computing the Reynolds number
For water, read from the Handbook's Properties of Water tables at the stated temperature, as in Fluid Properties. Here are a few rows of each.
| Temp. (°F) | (× 10⁻⁵ ft²/sec) | Temp. (°C) | (× 10⁻⁶ m²/s) |
|---|---|---|---|
| 40 | 1.664 | 5 | 1.518 |
| 50 | 1.410 | 10 | 1.306 |
| 60 | 1.217 | 15 | 1.139 |
| 70 | 1.059 | 20 | 1.003 |
Source: FE Reference Handbook, Properties of Water (English Units) and Properties of Water (SI Metric Units), selected rows
The SI table writes out its zeros, so 1.003 here is its 0.000001003. Re comes out unitless only if its inputs agree: ft/sec, ft, and ft²/sec, or m/s, m, and m²/s. A diameter left in inches makes Re twelve times too big. If a problem gives instead, use the form, with in slug/ft³ or kg/m³.
Most problems give a flow rate rather than a velocity. Put into Re, and you get a form worth having:
A duct that isn't round needs a stand-in for . The Handbook's section on Flow in Noncircular Conduits uses the hydraulic radius, the flow area over the wetted perimeter, and the hydraulic diameter, four times as big: . A full rectangular duct by wets all four sides:
Use in place of in Re. The hydraulic radius, a quarter of it, gives an Re four times too small.
The largest laminar flow
Run Re backward, and it tells you how far a flow can go before it stops being laminar. Set , then solve for the velocity in a given pipe, or the diameter at a given velocity:
The largest flow rate is that velocity times the area. For water, the answer is humbling. At 60°F in a 1 in. tube, ft/sec, about a foot every three seconds. Water in real pipes is nearly always turbulent, and laminar flow belongs to thick oils and thin tubes.
The Darcy-Weisbach equation
Now the loss itself. What ought to set it?
- Every foot of pipe has wall that drags on the water, so the loss should grow with the length .
- Faster water loses more. The eddies carry energy in proportion to the velocity head, as at a fitting, so the loss should follow .
- A bigger pipe has less wall per pound of water. The wall grows as and the water's area as , so the loss should fall as .
Put a pure number in front to cover everything else, and that's the Darcy-Weisbach equation, from the Handbook's Head Loss Due to Flow:
The friction factor has no units. Read as the pipe's length counted in diameters: each diameter of pipe costs velocity heads. With and in the same unit, comes out in the velocity head's unit.
This is the friction loss along the pipe, which is what the Handbook means by it. The Energy Equation let stand for a line's whole loss, and fittings add their to the friction found here. In a level pipe of one diameter, all of it comes out of the pressure, as the Handbook's Energy Equation section says: .
Problems often give instead of . Substitute , and you get a form the Handbook doesn't print but that's worth seeing:
Look at the powers. The loss goes as the flow squared, through the velocity head. It goes as one over the diameter to the fifth: four powers because the velocity goes as and then gets squared, and one more from . A small change in diameter makes a big change in loss.
Laminar friction
In laminar flow, the friction factor has a formula. The Handbook's Moody diagram, coming up next, labels its laminar line with it:
Put that into Darcy-Weisbach, and something changes. Re carries one power of , which cancels one from the velocity head, so the loss goes as , not . As a pressure drop:
That's Newton's law of viscosity scaled up to a pipe. In orderly layers, drag follows the velocity gradient, so twice the speed means twice the drag. Roughness doesn't appear at all: whatever a bump on the wall stirs up, viscosity damps out. The Handbook prints the same result solved for the flow, as the Hagen-Poiseuille equation under Pressure Drop for Laminar Flow: . Check that Re is below 2,100 before using either one.
Turbulent friction and the Moody diagram
Turbulent flow has no tidy formula for . The Handbook writes : it depends on Re and on the relative roughness , the height of the wall's bumps compared with the pipe's diameter. A bump that matters in a 2 in. pipe is lost in a 10 ft tunnel. The Handbook lists by material under its Moody diagram.
| Material | (ft) | (mm) |
|---|---|---|
| Glass, drawn brass, copper | smooth | smooth |
| Commercial steel, wrought iron | 0.0001–0.0003 | 0.03–0.09 |
| Galvanized iron | 0.0002–0.0008 | 0.06–0.24 |
| Cast iron | 0.0006–0.003 | 0.18–0.91 |
| Concrete | 0.001–0.01 | 0.30–3.0 |
| Riveted steel | 0.003–0.03 | 0.91–9.1 |
Adapted from the FE Reference Handbook, Moody, Darcy, or Stanton Friction Factor Diagram (roughness table), selected rows
Real pipes vary, so each material gets a range. Use a stated if there is one, or else the middle of the range, and put and in the same units before you divide.
Why should roughness matter only some of the time? Even in turbulent flow, the water touching the wall is held still, and a thin layer beside it keeps sliding in orderly layers. This viscous sublayer thins as Re rises. While it buries the bumps, the turbulence never feels them, and the pipe acts smooth. As Re climbs, the bumps poke through and shed eddies of their own. Once they all do, the bumps do the churning, viscosity stops mattering, and depends on alone.
The Handbook's Moody, Darcy, or Stanton Friction Factor Diagram puts all of this on one log-log chart: up the left side, Re along the bottom, and one curve for each , labeled at the right.
Adapted from the FE Reference Handbook, Moody, Darcy, or Stanton Friction Factor Diagram
Read the chart from left to right.
- Laminar flow: one line, , for every pipe.
- Critical zone: about 2,100 to 4,000, where the chart gives no .
- Transition zone: the curves slope down, so depends on both Re and . The name means the shift from smooth-pipe to fully rough behavior. To classify the flow itself, still use 2,100 and 10,000.
- Complete turbulence: each curve levels off, and depends only on .
To read , go up from Re on the bottom axis to the curve for your , estimating between curves if you need to, then go straight left.
The chart also says when the powers from the Darcy-Weisbach section hold exactly: in complete turbulence, where doesn't change with Re. Elsewhere it drifts a little, so scaling questions say to hold constant.
Running Darcy-Weisbach backward
The exam also runs the equation backward. It ties together five quantities, so given four you can find the fifth.
- For the velocity at an allowable loss, , and then .
- For the diameter that keeps a flow within an allowable loss, solve the flow-rate form, , and take the fifth root.
- For the friction factor from a measured pressure drop in a level pipe, turn the drop into a head, , then .
An allowable pressure drop becomes a head the same way. In real design, depends on the very and you're solving for, so you'd guess , solve, and check it on the chart. Here, is given.