Bearing Capacity
A footing fails when it shoves a wedge of soil out from under itself.
Before this Lesson
In October 1913, a new grain elevator at Transcona, near Winnipeg, was being filled for the first time. As the bins neared full, the concrete bin house began to sink, and within about a day it had tipped over to nearly 27°. One side drove several meters down into the clay. Beside it, the ground heaved up.
The bin house barely cracked. It was later jacked back upright and set on piers carried down to rock. What gave way was the soil, and it gave way in a telling shape: down under the load, and up beside it. Bearing capacity measures how hard the soil resists moving that way.
Down under the load, up beside it
Picture a long concrete strip footing, wide, with its base at a depth below the ground, and keep adding load. At first the soil under it just compresses a little. Push hard enough, though, and a wedge of soil directly under the footing locks onto the base and moves down with it as one block. The wedge can only go down by shoving the soil on either side out of its way, so that soil slides outward and upward along curved slip surfaces, and the ground beside the footing bulges up. That's a general shear failure, and three things resist it, numbered in the figure.
Three resistances, three terms
The Handbook's Geotechnical section gives the strength of that mechanism for a strip footing, under Ultimate Bearing Capacity:
is the average pressure under the base at which the soil fails, is the footing's width, and is the depth of its base. Each term is one of the three resistances, times a dimensionless bearing capacity factor that depends only on :
- , the cohesion term: cohesion along the slip surfaces. A wider footing has longer slip surfaces, but also more base for them to hold up, so per square foot of base, cohesion is worth times a fixed number.
- , the overburden term: the soil beside the footing, above its base, which the heave has to lift. It presses on the base level with , and that weight on the slip surfaces buys friction. The equation counts this soil's weight but not its strength, which is why the figure's slip surfaces stop at the base level. The Handbook calls the factor for depth.
- , the width term: the weight of the soil in the failure zone, which buys more friction. The zone's width and depth both grow in proportion to , so its weight grows with , and per foot of base, with . The is bookkeeping: values of are defined with it in place.
Only the width term grows with , and only the overburden term with , so keep them straight.
One symbol needs care. In its phase relationships, the Handbook uses for the buoyant unit weight, . Here it means the effective unit weight: buoyant where the soil is below the water table, and the ordinary moist value where it's above. Every footing in this Lesson has the water table far below its failure zone, so is simply the moist . Footing Size and the Water Table brings the water table up.
The factors climb steeply with . In one widely used set of values, is about 18 at and 64 at 40°. The Handbook prints no table of them, so exam questions give them to you.
Take away the friction
Now set the friction to zero, as it is for a saturated clay loaded faster than its water can drain. That's the undrained case from Shear Strength: , and the clay's strength is a fixed , which takes the place of .
A saturated clay's water takes years to escape, so a clay loaded over weeks or months is undrained: and . A clean sand drains as it's loaded, so it's drained, with . So is a clay in the long term, with and .
A soil with strength but no friction is like a tub of stiff putty. To push a board down into it at some depth, you have to beat the pressure already there at that depth, plus the putty's strength. Beside a footing, that pressure is , and with no friction it buys nothing more, because pressing harder on a slip surface doesn't make it stronger. So : the overburden counts once, at face value. For the same reason, the failure zone's own weight buys nothing, and .
The cohesion factor for comes from two classic solutions: 5.14, which is exactly , and Terzaghi's 5.7. A question gives you one of them, along with and .
Working the equation
With the terms sorted out, a bearing capacity problem is substitution. Strike out the terms that vanish, then evaluate the rest one at a time, in consistent units.
Now a footing on clay.
That's the contrast to carry away. On sand, a deeper or wider footing raises a lot, because every extra foot of or is multiplied by a large factor. On a clay, width does nothing for , and depth adds only . Transcona's clay was loaded in weeks, far faster than it could drain, and later analyses with its undrained strength predicted a failure pressure close to the one the full bins applied.
Ultimate is not allowable
is the pressure at which the soil fails, so no footing is designed for it: soil strengths are uncertain, and a footing that close to failure would settle far too much anyway. You divide by a factor of safety, often 3, which the question states. The Handbook stops at , so this step is yours:
is the allowable bearing pressure. A strip footing is long, so its load is given per unit length of wall, in kips per foot or kN per meter. Each foot of footing has square feet of base, so the allowable load per unit length is .
To check an existing footing, run it backward: divide its load per unit length, , by for the pressure it applies, and compare that with the ultimate:
The Handbook prints the same ratio for a retaining wall's base, as over the pressure at its toe.
Spreading the load: footings and mats
Every foundation takes a load gathered into a column or a wall and hands it to the ground at a pressure the soil can carry without failing or settling too much. Shallow foundations do it near the surface, by spreading out. A spread footing is a pad, usually square, under a single column. A wall footing is a continuous strip under a bearing wall, the strip footing of the bearing capacity equation. A mat, or raft, is one thick slab under the whole building.
Each footing's area is its column load over , so heavy loads on weak soil make the footings grow until they nearly touch. Once they'd cover more than about half the building's area, one slab is simpler and cheaper. A mat is also stiff, so it bridges over soft pockets and the building settles more evenly, which makes it the choice when differential settlement must be kept small. It still has a bearing capacity, though: Transcona sat on a mat.
A compensated mat goes a step further. Dig a basement deep enough that the soil removed weighs about as much as the building, and the stress under the mat ends up about where it started. It's a ship's trick: a ship floats by displacing its own weight of water. The soil carries about what it always did, so it barely settles, even when it's soft clay.
Going down to firm ground
Sometimes the soil near the surface is so soft or loose that a footing would fail, or settle too much, at any practical size. Then the load goes down through the weak soil on deep foundations, piles and drilled shafts. When rock or another firm layer lies within reach, they carry the load down to it, and the soft soil above barely feels it.
An end-bearing pile stands on a firm layer like a column on a footing: its tip pushes on the rock or dense soil. Where no firm layer is within reach, a friction pile carries its load along its sides instead, by skin friction with the soil, the way a nail holds in wood. Most piles do some of both, and the name says which does most of the work.
They also go in two ways. A driven pile of steel, precast concrete, or timber is made first, then hammered or vibrated into the ground. Driving densifies a loose sand around it, and the blows it takes give a field check on its capacity, but the hammering shakes the ground and can damage older buildings nearby. A drilled shaft is a drilled hole, often several feet across, filled with reinforced concrete. Drilling is nearly vibration free, one large shaft can carry a heavy column by itself, and its bottom can be drilled into rock as a rock socket.