Footing Size and the Water Table
Wet soil carries less, so the footing has to grow to make up for it.
Before this Lesson
- Bearing Capacity
- Unit Weights of Soil
- Combined Stresses · Mechanics of Materials
In Bearing Capacity, a strip footing 4 ft wide with its base 3 ft down in sand came out at ksf, with the water table far below. Keep the same sand, the same friction angle, the same footing, and let a wet spring bring the water table up to the ground surface. Now the soil fails at about 8.1 ksf. Nobody added a pound of load or weakened a single grain. The water came up, and the footing lost nearly half its capacity.
Water lifts the failure zone
Start with where each unit weight in the equation comes from:
The in the overburden term belongs to the soil beside the footing, above its base: is the pressure that soil puts on the base level. The in the width term belongs to the soil in the failure zone, below the base, which reaches down about one footing width. Both weights do the same job. They press the grains on the slip surfaces together, and pressed grains resist sliding by friction.
Below the water table, every grain sits in a tank. As in Unit Weights of Soil, the water pushes up on each grain with the weight of the water it displaces, so the grains press on each other with only the effective (submerged) unit weight, which the Handbook prints under Phase Relationships:
That's roughly half the moist unit weight. Friction doesn't care how heavy the soil is. It cares how hard the grains press together. So each term takes the unit weight of its own soil: the moist where that soil is above the water table, and where it's below. The Handbook prints the equation with in both terms and says nothing about the water table, so the sorting is yours:
- Water table far below. A water table deeper than about below the base touches neither body of soil, so both terms use the moist . That was every footing in Bearing Capacity.
- Water table at the base. The failure zone is under water, so the width term uses . The soil above the base is still above the water, so the overburden term keeps the moist .
- Water table at the ground surface. Both bodies of soil are under water, so both terms use .
The water doesn't change the sand's friction angle, so the factors stay put, and so does . And it's , not : the saturated unit weight includes the water, and the pore pressure carries that share, not the grain contacts.
If this sounds like Effective Stress, it is. The overburden term's is the vertical effective stress at the base level: with the water table at the base, with it at the surface. Find first, and the overburden term follows.
Run the Hook's footing through all three cases. Its sand weighs lb/ft³ moist and lb/ft³ saturated, so lb/ft³. Under water, the width term becomes psf, and the overburden term psf.
| Water table | Overburden term (psf) | Width term (psf) | (ksf) |
|---|---|---|---|
| Far below | 8,004 | 6,946 | 15.0 |
| At the base | 8,004 | 3,781 | 11.8 |
| At the surface | 4,357 | 3,781 | 8.1 |
Questions often say which terms take . When one doesn't, sort them by where the water table is.
Deeper, wider, wetter
Read the table down its rows. When the water table rose to the base, only the width term changed, and it shrank in the same ratio as the unit weight, , to a little over half. When the water rose on to the surface, the overburden term followed. That's the whole pattern: each term moves on its own, and how far moves depends on how much of it that term was carrying.
The footing's size works the same way. On sand, appears only in the overburden term and only in the width term, each to the first power. Bury the footing deeper and the overburden term grows in proportion; widen it and the width term does. Water doesn't stop either from helping, but each extra foot of depth or width is worth only about half as much when the soil involved is under water.
Sizing a footing
Here's where a wet site costs you. The allowable bearing pressure, , is divided by a factor of safety, often 3, so it falls with . When the water reaches the surface, the Hook's footing drops from about 5.0 ksf to about 2.7 ksf, and each square foot of it may carry little more than half what it could. A footing's job is to spread a column's load over enough ground that the pressure stays within , so sizing is a division:
A column carrying a dead load of 120 kips and a live load of 80 kips puts 200 kips on its footing. On soil with ksf, it needs 50 ft², a square spread footing ft on a side. A wall footing works per foot of wall: each foot of footing has square feet of base, so its width is the wall load per unit length over , with no square root. The Handbook prints none of this; it stops at .
The 200 kips is the service load: the dead and live loads the column really carries, unfactored. The Handbook's Loads (ASCE 7-16) prints it as the simplest allowable stress design combination, . The soil's margin is already in , through its factor of safety. The strength design combinations on the same page, such as , are for a different job: designing the footing's concrete, its thickness and reinforcement, the way every concrete member is designed.
Some questions add one more load: the footing itself and the soil backfilled over it. The ground feels them as surely as it feels the column. Picture what stands on each square foot of base: concrete as thick as the footing, then soil up to the ground. That much of is spent before the column gets any.
Whatever's left is what the column can have:
Off-center loads
So far the load has come down the middle, and the soil has pushed back evenly with . Now give the column a moment as well, from wind on the building, say. Look at the footing's base as a cross-section, the way you looked at a short post in Combined Stresses. It carries an axial load and a moment, so the contact pressure is , where is the base's section modulus.
Call the side along which the load shifts and the other side. Combined Stresses called that side , but footings use . The Handbook's area table gives a rectangle's , and with , . Write the moment as the load times its eccentricity, , and the bending part becomes a fixed multiple of the even part:
is the total vertical load on the base. For a wall footing, work per unit length: is times 1, and is the load per unit length. The Handbook prints the plus half for a retaining wall's base, under Retaining Walls, as .
Soil can push, but it can't pull. The minus sign gives the pressure at the far edge, , and it stays at or above zero only while
That's the middle third again: keep the load within it, and the whole base presses on the soil. Past , the formula asks the soil for tension at the far edge. Real soil can't supply it, so that edge lifts and the rest of the base takes more pressure than the formula says. A negative is a warning, not an answer.
How far off center
Turn the question around: how large a moment can a footing take? Two limits apply, and whichever comes first governs.
- The maximum pressure reaches . Set and solve for .
- The minimum pressure reaches zero, at .
Take the smaller , then . Which limit comes first depends on how hard the footing is already working. At , the maximum pressure is exactly , so a footing whose average pressure is more than half of reaches first, and a lightly loaded one reaches zero first.