BOD Kinetics
BOD is exerted fast at first and then ever more slowly, like a cooling cup of coffee.
Before this Lesson
- Oxygen Demand
- Mixing and Mass Loading
- Exponentials and Logarithms · Mathematics and Statistics
A lab hands you a wastewater's : 200 mg/L. That's the oxygen the bacteria used by day five, which is when the test stopped. Nobody told the bacteria. They keep eating for weeks, in the bottle or in a river.
So how much oxygen will this waste take in the end, and how quickly? One more number answers both: how fast the bacteria eat.
The same fraction every day
Bacteria eat what they can find. Plenty of food means plenty of eating, and as the food runs short, the eating slows. The simplest version of that idea says the rate of eating is proportional to the food still left. Call that , the BOD remaining: the oxygen the bacteria have yet to use.
That's first-order kinetics, and it means the same fraction disappears every day. Take per day, a common value for sewage at 20°C. Each day multiplies by , so about a fifth of whatever's left goes. Starting from 300 mg/L, that's 62 mg/L on the first day, then 49, then 39. Same fraction, smaller bites. Coffee cools the same way, losing heat in proportion to how far it still sits above room temperature. Starting from the ultimate BOD, , the BOD remaining decays exponentially:
Every bit of food eaten is oxygen used, so the BOD exerted is whatever no longer remains, . That gives the equation in the Handbook's BOD Exertion section:
The Handbook calls the BOD decay rate constant, in base per day, and writes the ultimate BOD with a small letter o, . It prints no typical , so a problem has to give you one.
Look at the rising curve. It climbs quickly, then ever more slowly toward . At this , day 5 is only about 68% of the way up. So the lab's 200 mg/L from the opening isn't the whole bill.
What's left, and constants in base 10
Problems also ask for the falling curve: how much BOD remains after days. The Handbook prints only the exerted form, so either use or subtract the exerted BOD from . Read the question's word carefully.
Watch the base, too. Some references state a base-10 constant, written with a capital :
It's the same curve in a different base. Since , the exponent just picks up that factor:
So the common per day is per day. The Handbook has only the base- form, so a constant labeled base 10 is your cue to convert before it goes anywhere near an . Skip that, and the bacteria look 2.3 times slower than they are.
Warm bacteria, same food
Warm a bottle and the bacteria eat faster. They don't get any more to eat. So temperature changes and never . The Handbook's Kinetic Temperature Corrections section adjusts from the standard test's 20°C to temperature :
Each degree multiplies by , so the correction compounds. At 20°C the exponent is zero and nothing changes. Below 20°C the exponent is negative and shrinks.
| Temperature | θ |
|---|---|
| 4–20°C | 1.135 |
| 21–30°C | 1.056 |
Adapted from the FE Reference Handbook, Kinetic Temperature Corrections
BOD gets two values, so check which side of 20°C you're on before you pick one. When a problem states its own , such as 1.047, use that.
Running the clock backward
Sometimes the unknown is or , stuck up in the exponent. Divide the exertion equation by . The ratio is the fraction exerted; call it . Then get the exponential alone and take the natural log:
To solve , take of both sides: . With below 1, is negative, so comes out positive. It has to be , because undoes powers of 10 and not powers of . For more, see Exponentials and Logarithms.
Notice that is gone. How long it takes to exert a given fraction depends only on . For half, and , the half-life the Handbook prints in its Radiation section for a biologically degraded contaminant. At per day, that's 3 days, where the two curves crossed in the earlier figure.
Speed versus food
Two numbers set the whole curve, and they do different jobs. is how fast the bacteria eat, which sets how quickly the curve closes in on its ceiling. is how much food there is, which sets how high that ceiling is. A reading depends on both, because it's a snapshot taken partway up.
A long test shows one more feature. Everything so far is carbonaceous demand. As Oxygen Demand noted, nitrifying bacteria also breathe oxygen as they turn ammonia into nitrate, and they grow slowly. In raw sewage they often get going only after a week or so, so a curve that looks ready to level off picks up a second rise. The and in this Lesson describe the first stage alone. The Handbook prints nothing on the second stage, and doesn't draw this curve.
Mix first, then decay
So far the bacteria have sat in a bottle. Now let the bottle float down a river. Follow one parcel of water from the outfall. The bacteria in it don't know they're moving, so the same decay runs, and the clock reads the parcel's travel time: distance over velocity .
That time has to be in days to match , which in U.S. units takes 5,280 ft per mile and 86,400 sec per day.
Write the balance first. The parcel's starting BOD is the fully mixed value just below the outfall, the same balance as in Mixing and Mass Loading:
So the order is: mix, turn distance into days, decay. The effluent's clock starts at the outfall, and from there the river's BOD and the effluent's decay together, as one mixed value.
The oxygen sag
BOD is the threat, but dissolved oxygen is what the fish feel. Follow the same parcel and watch its DO. Two things change it at once:
- Bacteria pull oxygen out, at a rate proportional to the BOD left, . The Handbook writes for this deoxygenation rate constant, the river's version of .
- Air puts oxygen back, at a rate proportional to the deficit , how far the water sits below saturation, . The emptier the water, the faster it takes oxygen in.
Just below the outfall, BOD is at its highest and the deficit is still small. The bacteria win, and DO falls. But that changes both rates. BOD is being eaten, so the bacteria's pull weakens. The deficit is growing, so the air's pull strengthens. Eventually they match, and at that moment DO stops falling. That's the low point, called the critical point. Beyond it the air pulls ahead and the river slowly recovers.
The Handbook's Stream Modeling section prints the Streeter Phelps equations behind this curve, including , though it doesn't draw the curve. This Lesson doesn't compute with them. To read the curve, you only need the two rates.
So to predict how the sag moves, ask what a change does to each rate. For temperature, two more facts help. In the Handbook's Kinetic Temperature Corrections, the for BOD above 20°C, 1.056, beats the 1.024 for reaeration. And warm water holds less oxygen: about 9.1 mg/L at 20°C against 7.6 mg/L at 30°C. The Handbook prints no saturation table, so a problem would supply those values.