Lateral Earth Pressure
How hard soil pushes on a wall depends on whether the wall moves away, stays put, or pushes back.
Before this Lesson
Two concrete walls each hold back 10 ft of the same dry sand. One is a basement wall, braced at the top by the first-floor slab and at the bottom by the basement floor. The other is a retaining wall beside a driveway, with nothing at its top. The basement wall gets designed for half again as much push from the sand.
The sand is identical. The difference is that the retaining wall is allowed to lean away from it by a fraction of an inch, and that barely visible movement cuts the sand's push by about a third. This Lesson works out why, and how big each push is.
Sideways is a fraction of down
Fill a tank with water, and at any depth the water pushes on the walls exactly as hard as it presses down. A fluid can't resist shear, so squeeze it one way and it presses out every other way equally. Now fill the tank with dry sand. The grains lean on one another, and friction at their contacts lets the pile carry part of its weight straight down through the grain skeleton. The walls feel only a fraction of the vertical stress, and that fraction is the coefficient of lateral earth pressure :
The primes matter. Friction belongs to the grains, so multiplies the vertical effective stress from Effective Stress. In this Lesson the backfill is dry, so and at a depth below its surface. Water in the backfill waits for Earth Pressure with Water and Surcharge.
Which fraction? That depends on what the wall does, and the simplest case is a wall that doesn't move at all. The soil behind it is then held sideways just as it was in the ground before anyone dug, neither squeezed nor allowed to spread. That's the at-rest state. The Handbook's Horizontal Stress Profiles and Forces gives its coefficient for a normally consolidated soil:
It's a rule fitted to measurements, not a derivation, hence the . The Handbook prints a second form for overconsolidated soil, which this Lesson leaves aside. For a sand with , : at rest, the sand pushes sideways half as hard as it presses down.
The pressure triangle
Since , the pressure on the wall is . It's zero at the top and grows in a straight line to at the base of a wall of height , so plotted against the wall it makes a triangle.
The total push on one foot (or one meter) of wall, measured along its length, is the triangle's area, half its base times its height:
That's a force per unit length of wall, in lb/ft or kN/m. It acts through the triangle's centroid, above the base: the push sits low, where the pressure is largest. Its overturning moment about the base is the force times that arm, .
Let the wall move
Now let the wall lean away from the backfill. The sand behind it follows, and to follow, a wedge of it has to slide down along a plane that runs up from the base of the wall. Sliding calls up friction along that plane, pointing up the slope, and the friction holds up part of the wedge's weight. Whatever the friction carries, the wall doesn't, so the push drops. It bottoms out when the friction is fully used and the soil fails: the active state, with coefficient .
Push the wall into the backfill instead, and the wedge has to be shoved up and out. Friction now points down the plane, against the motion, so the wall must lift the wedge and beat the friction too. The push climbs until the soil fails the other way: the passive state, , many times the at-rest push. The passive wedge is also longer and flatter, so there's more soil to shove.
The two limits need very different amounts of movement. Typical figures for sand, measured at the top of the wall, are about 0.1 to 0.4 percent of its height to reach active and about 1 to 4 percent to reach full passive, roughly ten times as much; for a medium-dense sand, call it 0.2 percent and 2 percent. The passive push has much farther to climb: from half of to several times it, where the active push only has to ease from a half to about a third. For a 10 ft wall in medium-dense sand, that's about a quarter inch to reach active and about 2.4 in for full passive. The Handbook doesn't give these figures.
That settles the two walls from the start. The retaining wall can lean a quarter inch without anyone noticing, so it's designed for . The basement wall, pinned by its floor slabs, can't, so it gets . A wall is designed for the state its movement allows.
Both limits are the failure circle
Active and passive are both failure, so they come straight from the circle in Triaxial Tests and Failure Planes. At a depth , the soil above fixes , and moving the wall changes only . At rest, the circle between and sits safely under the envelope.
For a sand, the circle touches the envelope when the ratio of the principal stresses reaches a value set by alone, whatever their size:
Let the wall move away, and falls while stays put. The circle's left end slides left and the circle grows until it touches the envelope. That's a triaxial test with as and as , so is the failure ratio upside down. Push the wall in, and climbs past . Now is the smaller stress, , and the circle grows to the right until it touches. The Handbook's Horizontal Stress Profiles and Forces prints both results:
Each coefficient there carries the fine print "smooth wall, , level backfill": a vertical wall with no friction against the soil, a cohesionless backfill, and a level surface. That's the case this Lesson covers. The two are reciprocals, , which makes a quick check. For , and , nine times as large, with between them.
| 25° | 0.406 | 0.577 | 2.46 |
|---|---|---|---|
| 30° | 0.333 | 0.500 | 3.00 |
| 35° | 0.271 | 0.426 | 3.69 |
| 40° | 0.217 | 0.357 | 4.60 |
The active push on a wall
A wall free to lean is designed for the active state, so goes into the triangle. The pressure at depth is , the resultant is per unit length, and it acts above the base. The Handbook's figure under Horizontal Stress Profiles and Forces prints this force for the top layer of a two-layer backfill, . With one dry layer, drop the 1s. The figure doesn't mark the , so carry that in.
Passive resistance in front of the wall
Passive pressure is what holds a wall back. A wall shoved by its backfill tends to slide away from it, into the soil in front of its toe, and that soil pushes back. So does soil beside a footing shoved sideways, and soil in front of an anchor block that a tie rod pulls through the ground. The triangle is the same with in it, but its height is only the depth of soil in contact, the embedment depth :
It acts above the bottom of the embedded face. The Handbook says only that passive forces are "similar to the active forces shown," so this is its active form with and in place of and . The height of the wall above doesn't enter. A 20 ft wall with 3 ft of soil in front of its toe gets passive help from those 3 ft only, and being large is what makes even that much worth counting.
What makes the push grow
Read the trends straight off . The unit weight appears once, so a heavier soil pushes harder in proportion. The height is squared: double it, and the triangle is twice as tall and twice as wide at its base, so it holds four times the area. The moment, whose arm doubles too, grows eightfold.
The friction angle works only through , and in opposite directions. A soil with more friction holds more of itself up when the wall leans away, so falls, and resists harder when it's shoved, so rises. falls with too. That's one reason retaining walls are backfilled with clean sand or gravel.