Steel Tension Members
A bolted plate is only as strong as its weakest path between the holes.
Before this Lesson
- Loads and Load Combinations
- Axial Stress · Mechanics of Materials
Take an A36 steel plate 6 in. wide and 1/2 in. thick. It's good for about 97 kips of factored tension. Now drill a hole through it for a 3/4 in. bolt. The design rules count 15% of the steel at that section as gone, and the plate is still good for 97 kips. Drill a second hole beside the first, and they count 29% as gone, yet the strength falls only to 92 kips.
The arithmetic is fine. A tension member can stop working in two different ways, and a hole matters to only one of them.
Stretching and tearing
Pull on a plate with bolt holes near its ends, and raise the load. The first steel to yield is beside the holes, where the section is smallest. It sounds alarming, and it doesn't matter. Say the plate is a 20 ft hanger and the yielded zone is about an inch long. Stretch that inch by 1% and the hanger grows by 0.01 in. Nobody will ever know.
From Axial Stress: the yield strength is the stress at which a ductile metal starts to stretch for good, and the ultimate strength is the highest stress it reaches before breaking. Steel design writes them and . The Tension Test puts them on a stress-strain curve.
Keep raising the load, and one of two things ends the member's job.
Yielding of the gross section. The plate reaches its yield stress along its whole length. Now all 240 in. are stretching, and 1% is 2.4 in. Whatever the hanger holds has dropped 2.4 in. and keeps dropping with almost no added load. Nothing has broken, but the member has stopped being useful, slowly and in plain sight. Most of the length has no holes, so this check uses the gross area .
Rupture of the net section. The steel at the holes doesn't stop at . It hardens and carries more, until it reaches the ultimate strength and tears. So this check pairs with the reduced area at the holes, the effective net area . A tear comes suddenly, and a sudden failure gets a smaller .
The Handbook lists both limit states under Tension Members: Flat Bars or Angles, Bolted or Welded. It writes the factors as and , where many references write for both. Each times its is a design strength:
The same list has values for ASD and a third limit state, block shear, which this Lesson leaves out.
Demand versus capacity works as it always does: , with from the combinations in Loads and Load Combinations. The design strength is the smaller of the two, though the Handbook doesn't say so. Compare them after each gets its own , because rupture's lower factor can change which is smaller.
A question states the stresses or names a grade. The Handbook's Table 2 - Average Mechanical Properties of Typical Engineering Materials gives A36 as 36 ksi and 58 ksi, printed as and . It lists no other structural grade, so a question using one states its values.
What's left at the holes
In Axial Stress, you cut straight across a hole and deducted its diameter: . Steel design keeps the cut and deducts more. A bolt hole is 1/16 in. larger than its bolt so the bolt will fit, and another 1/16 in. gets written off, the usual reason being that making the hole roughs up the steel around it. The Handbook gives and this net area, with the sum running over the holes the cut passes through:
If a question gives the hole diameter instead, the deduction is
Only holes on the cut count. Bolts side by side across the plate each take a deduction. Bolts in a line along the load take one between them, since a straight cut meets only one of them. For a bolted plate, which the Handbook calls a flat bar, the effective net area is simply the net area: .
A tear can zigzag
Stagger the bolts and a tear gets a choice. It can go straight across, through few holes, or zigzag from hole to hole, through more of them. Each extra hole makes the path easier. But each slanted leg is longer than the width it crosses, and all of that steel has to tear too.
How much longer? A leg that crosses while moving along the plate has length , which is about when isn't large. The Handbook gives back half of that extra, , for each diagonal:
Here is the spacing along the load and the spacing across it, between lines of holes. The Handbook writes the deduction here as , the same thing.
Why only half? Steel on a slanted line isn't simply pulled apart. Part of the load acts along the line as shear, so an inch of diagonal is worth less than an inch of straight cut. The term is a simple rule that tests back up, not pure geometry, so take it as printed.
The Handbook stops at the formula, but the plate tears wherever it's weakest, so you go looking. A tear runs from edge to edge and meets each line of holes once, without doubling back. Sketch each such path, work out its bracket in inches, and take the smallest. That's the critical path. Multiply by last, so that gets multiplied too.
When only part of the section is connected
Bolts across a plate's width feed load into every part of it. Now bolt an angle through one leg. The load enters through that leg, and the other leg, sticking out into space, gets its share only after the stress has spread around the corner, which takes distance. Near the connection, the connected leg is overworked and the outstanding leg is along for the ride, so not all of the net area counts. That's shear lag. The Handbook never uses the term, but it prints the factor that accounts for it:
, the Handbook's connection eccentricity, is the distance from the connected face to the member's centroid. is the length of the connection, from first bolt to last or along the weld, though the Handbook defines it only for welds. The formula reads the way it should: a centroid far off to the side lowers , and a longer connection gives the stress more room to spread, which raises it.
The Handbook has no angle table, despite its note to use tabulated areas, so a question gives you and , or itself. Start from , subtract for each hole on the cut, and then apply . A welded member has no holes, so its is just .
The Handbook also prints fixed values. A bolted flat bar, or a flat bar or angle with transverse welds, gets 1.0. A flat bar welded only along its edges takes load from the sides, so the middle lags, and runs 1.0, 0.87, then 0.75 as the weld length falls from toward the bar's width .
Which one governs?
Two questions sound alike here. The critical path is about geometry: which path leaves the least steel? The governing limit state is about strength: with that area in hand, is rupture weaker than yielding? A plate always has a critical path, and yielding can still govern. The Hook's plate shows how.
That crossing comes from setting the two strengths equal: , so . For A36 it's 0.745, so holes can take about a quarter of the section before they cost anything. For a steel with ksi and ksi it's 0.923, so rupture takes over after only 8%. The stronger steel gained more in than in , which leaves less room.