Steel Column Strength
Real columns buckle sooner than Euler predicts, and the AISC curve accounts for it.
Before this Lesson
In Slenderness and the Governing Axis, a W14X48 column stood 30 ft tall, pinned at both ends, with girts bracing its weak axis at midheight. Euler's formula gave it 454 kip, at a stress of 32.2 ksi, safely under the steel's 36 ksi proportional limit. By every test that Lesson had, Euler's formula held.
Make that column of 50 ksi steel and design it by AISC, and its nominal strength is 368 kip, about four-fifths of Euler's load. The resistance factor then takes it to 331 kip. That first cut isn't a safety margin. It's the difference between Euler's perfect column and a real rolled one.
What Euler assumed
Euler's derivation pictured a column that is perfectly straight and carries no stress at all until the load arrives. A rolled steel column is neither.
It's crooked. Mill tolerances let a W-shape come out bowed by an amount of about 1/1000 of its length, so a 30 ft column can be 3/8 in out of straight. A perfect column stays straight right up to . A bowed one bends from the first kip: the load, offset by the bow, puts a moment on the column, the moment bows it further, and the bigger bow adds moment. The bending piles extra compression onto the inside of the bow, so that face yields early.
It's already stressed. A W-shape comes off the rolls red hot and cools unevenly. The flange tips, thin and open to the air, cool and stiffen first. The thick junction where the web meets each flange cools last, and as it shrinks, the stiff tips resist it. Once it's cold, the junction is left in tension and the tips in compression, with no load on the column at all. These are residual stresses.
Now load the column. Every fiber carries its residual stress plus the average , so the tips, which started out squeezed, reach first, while the average is still well below it. A yielded fiber keeps its load but stops resisting: push it further, and it just gives. And the tips are the part of the section farthest from the web, the part that supplies most of a W-shape's . So the column loses its weak-axis stiffness early and buckles below Euler's stress.
That's the catch in the last Lesson's proportional-limit check. A test bar cut from the steel stays linear up to its proportional limit, but the whole rolled section, squeezed at its tips by its own cooling, goes soft sooner. The Handbook's column equations never mention either flaw, but they're calibrated for both.
AISC's column curve
The Handbook's Design of Steel Components section gives AISC's answer under Columns. It starts from Euler's critical stress, renamed the elastic buckling stress:
with ksi, printed in the section's heading. Then it chooses one of two critical stresses by slenderness:
The Handbook writes the conditions with , where , the same effective length.
Slender columns buckle elastically. Their buckling stress is so low that even the squeezed tips haven't yielded, so residual stress doesn't matter. Only crookedness does, and AISC charges a flat 12% for it: is 0.877 times Euler's stress.
Stockier columns buckle inelastically, with their tips already yielded. Their equation is times a factor, 0.658 raised to . As a column gets stockier, grows, the exponent shrinks toward zero, and the factor climbs toward 1. The stubbiest column doesn't buckle at all; it squashes at . That's also how to remember which way up the exponent goes. Write it by mistake, and a stocky column, with its enormous , gets almost no strength.
The switch at falls where Euler's stress has dropped to . There both equations give about , so the curve runs on without a jump. For 50 ksi steel:
The marked column is the Hook's W14X48. Its of 94.2 is below 113.4, so it buckles inelastically:
That's 81% of Euler's 32.2 ksi. Times the column's 14.1 in², it's the 368 kip nominal strength from the Hook.
Design strength, start to finish
Strength is stress times area, and the Handbook's nominal strength uses the gross area: . Its resistance factor for columns is , so the design strength, checked against the factored load as demand versus capacity, is
For the Hook's column, kip. The Handbook gives this for members without slender elements, flanges or webs thin enough to ripple locally first. None of Table 1-1's W14, W12, or W10 shapes has one.
From Slenderness and the Governing Axis: a brace shortens the unbraced length about one axis only, so compare with , and the larger governs. Lengths go in inches, to match .
From Euler Buckling, Table C-A-7.1 gives , theoretical and then recommended:
- pinned–pinned: 1.0 and 1.0
- fixed–pinned: 0.7 and 0.80
- fixed–fixed: 0.5 and 0.65
- fixed–free: 2.0 and 2.10
Every column problem runs the same chain. Find the effective length about each axis, divide each by its own , and keep the larger . Find , compare with the switch, take from the right equation, and multiply by . The costliest slip is the first one: reaching for out of habit, when it's usually the weak axis that governs.
Table 4-14: the curve, worked out
The Handbook's Table 4-14, Available Critical Stress for Compression Members, has run the equations for you. It lists in ksi, already multiplied by 0.90, for every whole from 1 to 200. Like Table 3-2 for beams, it's for ksi only, so it's no help with A36. And its values are stresses: multiply by to get a strength in kips.
| (ksi) | (ksi) | ||
|---|---|---|---|
| 81 | 27.9 | 91 | 24.6 |
| 82 | 27.5 | 92 | 24.2 |
| 83 | 27.2 | 93 | 23.9 |
| 84 | 26.9 | 94 | 23.6 |
| 85 | 26.5 | 95 | 23.3 |
| 86 | 26.2 | 96 | 22.9 |
| 87 | 25.9 | 97 | 22.6 |
| 88 | 25.5 | 98 | 22.3 |
| 89 | 25.2 | 99 | 22.0 |
| 90 | 24.9 | 100 | 21.7 |
Adapted from the FE Reference Handbook, AISC Table 4-14: Available Critical Stress φcFcr for Compression Members
The Hook's column has , between the rows for 94 and 95. Interpolating gives 23.5 ksi, and kip, just as the equations gave. Rounding up to the 95 row instead gives 23.3 ksi and 329 kip, a hair low, which is the safe side.
Table 4-1: strength by shape and length
Table 4-1, Available Strength in Axial Compression, goes one step further and multiplies by too. For fifteen W14, W12, and W10 shapes of 50 ksi steel, it lists in kips against the effective length in feet. Here are its rows from 8 to 16 ft:
| KL (ft) | W14X74 | W14X68 | W14X61 | W14X53 | W14X48 | W12X58 | W12X53 | W12X50 | W12X45 | W12X40 | W10X60 | W10X54 | W10X49 | W10X45 | W10X39 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 8 | 878 | 804 | 721 | 585 | 529 | 689 | 628 | 551 | 495 | 439 | 717 | 643 | 585 | 505 | 435 |
| 9 | 853 | 781 | 700 | 557 | 504 | 670 | 610 | 526 | 472 | 419 | 698 | 625 | 569 | 483 | 415 |
| 10 | 826 | 755 | 677 | 528 | 477 | 649 | 590 | 499 | 448 | 397 | 677 | 607 | 551 | 460 | 395 |
| 11 | 797 | 728 | 652 | 497 | 449 | 627 | 569 | 471 | 422 | 375 | 655 | 586 | 533 | 435 | 373 |
| 12 | 766 | 700 | 626 | 465 | 420 | 603 | 547 | 443 | 396 | 351 | 631 | 565 | 513 | 410 | 351 |
| 13 | 734 | 670 | 599 | 433 | 391 | 578 | 525 | 413 | 370 | 328 | 606 | 543 | 493 | 384 | 328 |
| 14 | 701 | 639 | 572 | 401 | 361 | 553 | 501 | 384 | 343 | 304 | 581 | 520 | 471 | 358 | 305 |
| 15 | 667 | 608 | 543 | 369 | 332 | 527 | 477 | 354 | 317 | 280 | 555 | 496 | 450 | 332 | 282 |
| 16 | 632 | 576 | 515 | 338 | 304 | 500 | 452 | 326 | 291 | 257 | 528 | 472 | 428 | 306 | 260 |
Adapted from the FE Reference Handbook, AISC Table 4-1: Available Strength in Axial Compression, kips—W shapes
The table's length is in feet, so there's nothing to convert; only needs inches. And it's taken, in the table's words, "with respect to least radius of gyration ": the table assumes the column buckles about its weak axis, so you enter it with . For an unbraced column, that's always right. With weak-axis bracing, check the strong axis first. If is the larger ratio, the table overstates the strength, and you need the equations or Table 4-14 instead.
It agrees with what you've computed. The Hook's W14X48, with ft, reads 332 kip, and the worked example's W14X61, at 13 ft, reads 599.
To select a column, run across the row for your . Each depth group runs from heaviest to lightest, so in each one, find the lightest shape that reaches . Then compare the three winners' weights. The deepest group doesn't always hold the lightest column.