Slenderness and the Governing Axis
A column buckles about whichever axis gives the largest .
Before this Lesson
- Euler Buckling
- Composite Sections · Statics
Euler's formula makes a strange promise. Halve a column's length, and its critical load goes up four times. Halve it again, and it's sixteen. Nothing in the formula ever says stop. So try it on a stub: a 1 in square steel bar, 6 in long, between two pins.
That's 663 kip on one square inch, a stress of 663 ksi. A36 steel yields at 36 ksi, so the stub squashes at about 36 kip, nowhere near the promise. Somewhere between the strand of spaghetti and this stub, Euler's formula stops telling the truth. To find where, think in stresses instead of loads.
One number for slenderness
Divide the critical load by the column's area, and you get the stress in the column at the moment it buckles:
That is the square of the radius of gyration, , so the length and the section merge into a single ratio:
The Handbook prints this under Columns, in its Mechanics of Materials chapter, as the critical buckling stress for long columns, and it calls the effective slenderness ratio. As in Euler Buckling, this Lesson writes the length as .
Look at what got folded together. is how long the column is, is how its ends are held, and is how far its area spreads from the axis it bends about. All of the column's geometry comes down to one number, : its effective length, measured in radii of gyration. Two steel columns with the same buckle at the same stress, whether one is a rod you could hold in your hand or a column in a ten-story building. And the stress falls with the square: double , and drops to a quarter.
Like , belongs to an axis: the one the column bends about when it bows. For a rectangle, use the side it bows across. A 2 in by 3 in bar bowing across its 2 in side has .
From Composite Sections: is the distance at which all of the area would give the same . The Handbook defines it under Radius of Gyration in its Statics chapter, and its area table prints for each shape:
The table writes circles with the radius , so a solid one has . A W shape's values are in Table 1-1, under Axis X-X and Axis Y-Y.
has no units, but only if and share them. Lengths usually come in feet and in inches, so multiply the feet by 12 first.
Where Euler stops telling the truth
Plot against , and the curve climbs without limit as columns get stockier. At , the stub from the start, it's at 663 ksi.
The trouble is an assumption Euler's derivation made without saying so: the column is as stiff as right up to the moment it buckles. is the slope of the straight first part of the stress-strain curve, as the Handbook's Uniaxial Stress-Strain section puts it. That straight part ends at the proportional limit, , the highest stress at which stress is still proportional to strain. Past it, each extra ksi buys more strain than before. The material is softer than says, and soon it yields.
So Euler's formula holds only while the critical stress stays at or below the proportional limit. Set the two equal, and solve for the slenderness where they meet:
For steel with ksi, that's . Euler's formula is valid for any column at least that slender. To turn the limit into the shortest length, multiply back by and divide by .
A column more slender than the limit is a long column. It buckles elastically, at Euler's stress, and the material never notices. A stockier one is an intermediate column. On its way to Euler's stress it passes the proportional limit, part of its section starts to yield, and its stiffness drops. It fails below Euler's curve, and never above the yield strength. That's why Euler overpredicts a stocky column: it credits the column with a stiffness it no longer has. The very stockiest, called short columns, skip buckling and simply squash.
The Handbook's Columns section prints its stress formula for long columns without saying where "long" ends, and the Handbook lists no proportional limit: its Table 2 gives only yield and ultimate strengths. So a question that wants this limit states . Use it, not the yield or ultimate strength, which are higher and would call some columns long when they're not.
Codes and textbooks draw the line between long and intermediate in different places, so a question that asks you to classify a column will state its transition value. Find and compare: above the value is long, at or below it is intermediate.
Each axis has its own KL/r
Euler Buckling said a column bows about its weak axis. That's true when its ends are held the same way in every direction and nothing touches it in between. Real columns often get help in one direction only. Horizontal wall members called girts tie into a column's flange and stop it moving along the wall, but not out of it. Sheathing nailed to a stud keeps it from bowing across its thin side.
A brace stops the column moving in one direction, so it shortens the unbraced length for buckling about one axis only. Each axis gets its own effective length and its own slenderness ratio, and . Both share and , so the larger ratio gives the lower stress, and that's the one the column reaches first. The column buckles about the axis with the larger KL/r. The Handbook's Columns formulas take one and one length, so run them once per axis.
Keep each length with its own . For a W shape, buckling about x bows the column in the plane of its web, and buckling about y bows it sideways, along its flanges. runs between points braced against the first, and between points braced against the second. Dividing the braced length by , or the full length by , mixes the two.
| Shape | (in²) | (in) | (in) |
|---|---|---|---|
| W14X48 | 14.1 | 5.85 | 1.91 |
| W12X79 | 23.2 | 5.34 | 3.05 |
| W10X49 | 14.4 | 4.35 | 2.54 |
Adapted from the FE Reference Handbook, Table 1-1: W Shapes Dimensions and Properties
A midheight brace halves . Whether the weak axis still governs depends on how compares with . With the same both ways, the strong axis takes over when is less than twice . Deep, narrow shapes like the W14X48 have about three times . The squat, heavy shapes made for columns are closer to 1.7.
A steel column this long buckles elastically. For a stockier one, Steel Column Strength takes the same governing into AISC's design curve.
Different ends, and the balance point
End conditions can differ by axis too. A strut held at each end by a single pin through a clevis can turn about the pin, but the clevis plates clamp its sides, so it acts pinned for buckling one way and close to fixed the other. Then and differ, and the same comparison picks the axis.
Bracing can also go too far. Add weak-axis braces, and drops until it matches . That's the balance point, where both axes are equally critical:
For a rectangle, is just the ratio of its sides, since the cancels. A pin-ended 2 in by 6 in bar is balanced with braces at its third points. Past the balance point, the strong axis governs, and more weak-axis bracing buys nothing.
Where a brace does the most good
Every brace is a bet on one axis. It pays only if it shortens the unbraced length that governs, and three rules follow from that:
- Brace the axis that governs. A brace about the other axis lowers a ratio that wasn't in charge.
- Split the longest segment, near its middle. Between braces, a column buckles over its longest unbraced piece. A brace that splits a shorter piece, or sits near an end of the longest piece, barely touches the governing length.
- Stop at the balance point. Once the other axis governs, more bracing on the first buys nothing.