Steel Beam Flexural Strength
A steel beam keeps carrying load after it starts to yield, until the whole section has yielded.
Before this Lesson
- Design Moments and Shears
- Loads and Load Combinations
- Bending Stress · Mechanics of Materials
Put a W18X50 of 50 ksi steel, with a slab on its top flange, under a slowly growing moment. The flexure formula says its top and bottom fibers reach yield when hits 50 ksi, at 370 ft-kip. If the beam were glass, that would be the end of it.
It isn't. The beam keeps taking moment, up to about 421 ft-kip, and even then it doesn't snap. It folds, slowly, like a bent paperclip. Those extra 50 ft-kip come from fibers that have yielded but haven't quit, and the Handbook's steel beam strength counts on every one of them.
Yielding spreads inward
From Bending Stress: plane sections stay plane, so strain grows in a straight line from the neutral axis, and in the elastic range , with in Table 1-1.
From Reading Stress-Strain Curves: idealized as elastic-perfectly plastic, steel's stress rises as to at a strain , then stays flat at .
At first yield the stress over the depth is the familiar triangle, with at both faces. The moment there is the yield moment:
For the W18X50, that's in.-kip, or 370 ft-kip. Now push past it. The strain keeps growing in a straight line, but the stress can't follow: a fiber strained past stays at . So the yielded zones creep inward from both faces, and only a core around the neutral axis is still elastic.
With the faces at , the elastic core is the middle half of the depth. At , it's the middle tenth. For 50 ksi steel that's a strain of only 0.017, and structural steel stretches to 0.2 or more before it breaks. So the core shrinks almost to nothing, and the limit, with every fiber at , is the plastic moment, . Past it, more bending buys no more moment. The section just keeps rotating, like a stiff hinge, and that's the Hook's paperclip.
Two blocks of stress
At the stress is two blocks: in compression on one side of the axis and in tension on the other. The beam carries no axial force, so the push and the pull must balance, and with the same on both sides, that means equal areas. So the plastic neutral axis (PNA) splits the section into two equal areas. For a symmetric section like a rectangle or a W-shape, that's mid-depth. For a T-section, it isn't at the centroid.
Each half carries at its own centroid, so the two forces form a couple, and everything in its moment except is geometry. That geometry is the plastic section modulus, :
Here and run from the PNA to the centroids of the compression and tension halves. For a rectangle wide and deep, each half is , with its centroid from the axis:
So a fully yielded rectangle carries 1.5 times its first-yield moment, and that's why , not , sets the plastic moment. describes the triangle, where only the extreme fibers reach and the fibers near the axis loaf. describes the two blocks, where every fiber works at .
A W-shape gains much less. In Bending Stress, the W18X50's web-flange junction ran at 94% of its face stress, so at first yield the flanges are already nearly yielded through. Full yield adds a lot in the web, but the web is thin and close to the axis.
The Handbook defines only as the "plastic section modulus about the x-axis," with no formula, and Table 1-1 lists it beside under Axis X-X.
| Shape | (in³) | (in³) | |
|---|---|---|---|
| W24X68 | 154 | 177 | 1.15 |
| W21X44 | 81.6 | 95.4 | 1.17 |
| W18X50 | 88.9 | 101 | 1.14 |
| W16X36 | 56.5 | 64.0 | 1.13 |
| W12X40 | 51.5 | 57.0 | 1.11 |
Adapted from the FE Reference Handbook, Table 1-1: W Shapes Dimensions and Properties. The last column is computed.
Across all of Table 1-1, beats by 10 to 18 percent, most for deep, light shapes like the W21X44, which carry more of their area in the web.
What can stop a beam short of full yield
assumes every fiber gets to yield. But a beam's compression side is made of thin plates being squeezed, and a thin plate squeezed hard enough can buckle before it yields, in two ways.
Local buckling
Stand on an empty soda can, and its thin wall wrinkles instead of shortening evenly. A flange or web too thin for its width can ripple the same way before it yields. A section stocky enough to yield all the way through before it ripples is compact. Most W-shapes are compact in 50 ksi steel, and Table 1-1 flags the few that aren't with its note f, "Shape exceeds compact limit for flexure," such as the W12X65. The Handbook prints no limits, so a question names a compact shape or says so.
Lateral-torsional buckling
Hold a plastic ruler on edge and try to bend it the stiff way. It rolls over sideways and twists instead. A W-shape's compression flange, the top one under positive moment, is a long, slender column being squeezed. The web keeps it from buckling downward, but nothing stops it from bowing sideways, while the stretched bottom flange hangs back. So the section swings sideways and twists: lateral-torsional buckling.
The cure is the one for any column: shorten it. A brace is anything that keeps the compression flange from moving sideways or the section from twisting, and the Handbook's unbraced length, , is the length between braces. A slab or metal deck fastened along the top flange braces it everywhere, which is full lateral support. The supports always count, since the Handbook notes that bracing must always be provided there.
Short enough, and the flange yields before it can buckle. The Handbook's rule: when , lateral-torsional buckling doesn't apply. Table 3-2 lists , which grows with the shape's weak-axis , and it's short: 5.83 ft for the W18X50. That beam spanning 30 ft, braced only at its supports, has five times and can't get near .
Past , the Handbook's next equation cuts below , and this Lesson stops there. So needs three things: a doubly symmetric I-shape such as a W-shape, bent about its strong axis; a compact section; and , which full lateral support satisfies.
Design strength
Now the check from Loads and Load Combinations, demand versus capacity, , in its bending form: . The Handbook's Design of Steel Components section gives for these beams, and its Yielding equation gives . Together:
in ksi times in in.³ gives in.-kip, so divide by 12 before comparing with an in ft-kip. The grade matters too. Table 3-2's heading assumes ksi, the usual grade for W-shapes, and a question that names A36 means 36 ksi, from the Handbook's Table 2 of material properties.
Table 3-2 also lists , the product already worked out: 379 ft-kip for the W18X50. It's a handy check, but only for 50 ksi. Used for A36, it would overstate the strength by 50/36.
Running it backward
From Design Moments and Shears: factor the loads first, then run the beam once. A simple beam under a factored uniform load peaks at midspan with .
Any piece of can be the unknown. Leave unknown, and the check becomes a requirement:
with in in.-kip. Any compact, braced W-shape with at least that is strong enough in bending. Picking the lightest one is the job of Selecting Steel Beams.
How much a beam can carry
Run it the other way, with the shape given and the load or the span unknown. Set in and solve:
Keep in ft-kip and in ft, and comes out in kip/ft. That is everything the beam can hold up, its own weight included. The designation gives the weight: a W18X50 weighs 50 lb/ft, or 0.050 kip/ft. It's dead load, so factored it's kip/ft. When a question asks what the beam can carry in addition to its own weight, subtract that.
The ASD side
ASD keeps the loads at service level and puts the whole margin on the strength, as . For these beams, the Handbook prints a single number, , beside . Call it , for bending. The Handbook prints no ASD equation and Table 3-2 has no ASD column, so you divide the nominal strength yourself:
For the W18X50, ft-kip, so the allowable moment is ft-kip, against a design strength of 379. ASD isn't stricter. Its 252 is compared with service moments, which carry no load factors. The ratio, , is what comes to over when the live load is three times the dead load, and at that mix the two methods agree.