Selecting Steel Beams
Pick the lightest beam that's strong enough, then make sure it isn't too bouncy.
Before this Lesson
In Steel Beam Flexural Strength, a 30-ft floor beam needed 360 ft-kip, and a W18X50 passed. It works. But the Handbook's Table 3-2 lists three shapes that carry about that much: a W14X61 good for 383 ft-kip, the W18X50 for 379, and a W21X48 for 398.
They weigh 61, 50, and 48 lb/ft. The deepest is the strongest, and also the lightest. Steel is bought by the pound, so on a floor of fifty of these beams, the W21X48 instead of the W14X61 saves 19,500 lb, almost ten tons of steel, for a floor that's no weaker.
Depth buys strength cheaply
Why would the deepest beam be the lightest? At the plastic moment, each flange is fully yielded and carries a force , one squeezed and one stretched, about apart. That's a couple, so the flanges' share of is their area times the lever arm, , and the web adds the rest.
The W14X61's flanges are 6.44 in.² each, on a lever arm of 13.3 in. The W21X48's are just over half that, 3.50 in.², but on a 20.2-in. arm, and its deeper web makes up the difference. Weight is just area: at the Handbook's 0.282 lb/in.³ for steel, each square inch of section weighs 3.4 lb per foot. The W21X48's flanges have 5.9 in.² less steel, about 20 lb/ft, and its taller web adds back only 2.2 in.², about 7 lb/ft: the Hook's 13 lb/ft. Depth is cheap because it costs only web, and the web is thin. It can't grow forever, though, because a floor has only so much room.
Reading Table 3-2
The Handbook's Table 3-2, W Shapes – Selection by , lists W-shapes of 50 ksi steel from largest to smallest, with already worked out in ft-kip, so you enter it with directly. It also lists and the design shear strength , for later. Blank rows split it into groups, and each group's first shape is in bold.
| Shape | (in.³) | (kip-ft) | (in.⁴) | (kips) |
|---|---|---|---|---|
| W21X48 | 107 | 398 | 959 | 217 |
| W16X57 | 105 | 394 | 758 | 212 |
| W14X61 | 102 | 383 | 640 | 156 |
| W18X50 | 101 | 379 | 800 | 192 |
| W10X77 | 97.6 | 366 | 455 | 169 |
| W12X65 | 96.8 | 356 | 533 | 142 |
| W21X44 | 95.4 | 358 | 843 | 217 |
| W16X50 | 92.0 | 345 | 659 | 185 |
| W18X46 | 90.7 | 340 | 712 | 195 |
| W14X53 | 87.1 | 327 | 541 | 155 |
| W12X58 | 86.4 | 324 | 475 | 132 |
| W10X68 | 85.3 | 320 | 394 | 147 |
| W16X45 | 82.3 | 309 | 586 | 167 |
| W18X40 | 78.4 | 294 | 612 | 169 |
| W14X48 | 78.4 | 294 | 484 | 141 |
| W12X53 | 77.9 | 292 | 425 | 125 |
| W10X60 | 74.6 | 280 | 341 | 129 |
Adapted from the FE Reference Handbook, AISC Table 3-2: W Shapes – Selection by Zx. Three of its nine groups, without the columns for unbraced beams.
The Handbook never says what bold means, but the table shows it: every other shape in a group is heavier than its bold shape and no stronger, and every shape above a bold one weighs at least as much. So a bold shape is the lightest beam with at least its strength, and selection takes three moves:
- Read up the column from below to the first shape with .
- Keep reading up to the nearest bold shape, or stop if you're on one. That's the lightest beam strong enough.
- Add the beam's own weight and check again.
The Hook's beam carries a factored 3.2 kip/ft over 30 ft, not counting its own weight, so ft-kip. Reading up, the W12X65's 356 falls short and the W10X77's 366 is enough. Stopping there is the trap: the W10X77 works, at 77 lb/ft. Every shape above it in the group works too, and the bold W21X48 is the lightest.
Use as printed. It already allows for the few shapes that aren't compact, such as the W21X48, whose 398 is a little under . It holds only for 50 ksi, though. For A36, find , with in in.-kip, and read up the column instead; the bold shapes still mark the lightest.
The beam's own weight
usually arrives without the beam's weight, since nobody knew the beam yet. Once you have one, add 1.2 times its weight to : the Hook's 3.2 kip/ft becomes kip/ft, and ft-kip, still under 398. Self-weight is a percent or two of the load, so it matters only when sits just under a bold shape's strength, and then it pushes you up a group.
When the depth is limited
The number after the W is the nominal depth in inches, a family name close to the true depth : Table 1-1 gives 13.9 in. for the W14X61. To save headroom, a question may limit the beam to, say, a nominal 14 in., which allows the W14s and anything shallower.
The bold shortcut is out now, since the bold shape is likely too deep. But within one nominal depth, weight climbs with , so reading up from the first adequate shape, the first W14 you reach with enough strength is the lightest W14 that works, and likewise for each shallower depth. Take the lightest of those. For the Hook's beam, a 16-in. limit gives the W16X57 and a 14-in. limit the W14X61: 48, then 57, then 61 lb/ft. Headroom costs steel.
Shear: the web does the work
From Shear Stress in Beams: the shear stress jumps by where a flange meets the web, and inside the web it stays nearly level. The flanges carry little shear, and the web carries most of : in a W18X50, about 96% of it.
So the Handbook's shear strength gives the web all of it, at one uniform stress, over a strip as deep as the whole beam: , "the overall depth times the web thickness." Steel yields in shear at about , so
with , and the Handbook's Shear section gives for the webs of rolled I-shaped members, not bending's 0.90:
Table 3-2 prints this as , for 50 ksi; for another grade, compute it from and . The one exception in the Handbook's tables is the W24X55, whose note v marks a web too slender to count on yielding before it buckles, so its tabulated value already uses . ASD divides by the Handbook's for shear, written here, and compares with the shear from service loads.
Why shear rarely governs
Under a uniform load, and , so : the longer the span, the less shear comes with each ft-kip of moment. The Hook's W21X48 sees kips against 217, and shear would govern it only on a span under ft. In shear alone, a span can carry .
A heavy load near a support
A point load breaks the rule. With a distance from the left support and from the right, the near reaction is , and the moment under the load is . Slide the load toward the support, and climbs toward all of , while the moment shrinks with its lever arm .
So a short beam that picks up a column near one end needs at the near support checked against , even when bending passes easily.
Too bouncy: deflection
From Beam Deflection: the Handbook's table Simply Supported Beam Slopes and Deflections gives a full-span uniform load's midspan sag as . Work in kips and inches, with in kip/in. (kip/ft divided by 12) and ksi, the value at the top of the Handbook's steel design section. With more than one load, add each one's sag at the same point, as in Beam Deflection by Superposition.
A beam can be plenty strong and still sag enough to crack the plaster under it or bounce underfoot. That's a serviceability limit state, from Loads and Load Combinations: nothing comes down, but the floor doesn't do its job on an ordinary day. So the check uses service loads, with no load factors.
Often it uses the live load alone. The dead load's sag happens once, before the partitions and ceilings go in. What cracks them is the extra sag each time the room fills up. The Handbook prints no deflection limits, so the question states one, most often under live load: 1.00 in. on a 30-ft span. Set the sag against the limit:
Turning the check around
The same inequality gives the longest span or the largest load. The limit grows with the span, so one cancels, and the span enters as :
A span 10% longer sags 46% more but is allowed only 10% more, which is why deflection tends to take over on long, lightly loaded beams.
Stiffness, not strength
A stronger steel won't fix a beam that sags too much, because appears nowhere in . does, and every structural steel has the same one: the Handbook's 29,000 ksi for steel design, and the same ksi for A36 in its Table 2. A stronger steel follows the same stress-strain line and only goes higher before it yields.
Under service loads a beam stays on that shared line, so the same shape in either grade sags exactly the same. The cure is a larger , and since the flanges supply most of it at about from the axis, grows with roughly the square of the depth. Go deeper.